GROUP BUTTON RELAY CIRCUIT - PART 9

GROUP BUTTON RELAY CIRCUIT




NWWNR (Normal Common Point Button Relay)

- When NWWN button is pressed , NWWNR is energised provided SMR is in picked up condition and RWWNR is in droped condition .

- When NWWNR relays are energized, thenn WNCR relay is dropped.

RWWNR

- When RWWN- Pressed , RWWNR- energized, Provided SMR (), NWWNR().

- When RWWNR - Energized, then WNCR ()


GBNR

- When GBN- Pressed , GBNR- energized, Provided SMR ().

GRNR

- When GRR- Pressed , GRNR- energized, Provided SMR ().

EOVNR

EOVR: Pressed, EOVNR: Energized , Provided SMR() condition.


EWNR

- EWWN  : Pressed, EWWNR: Energized , Provided SMR() condition.

EGGNR

- When EGGN- Pressed, EGGNR- Energised. 
- Whenever it is required to put back a signal to ON position during emergency , it can be done by pressing the signal button concerned alone with the EGGN button, as SM controlling relay front contact is not provided in both the circuits.


EUYNR

EUYR: Pressed, EUYNR: Energized , Provided SMR() condition.

CH1NR

- When CH1N- Pressed, CH1NR- Energized, Provided 
  1. SMR (↑), GNCR(↑), UNCR(↑).
  2. No point Button is pressed.
  3. No Siding Button is Pressed


CH2NR

When CH2N- Pressed, CH1NR- Energized, Provided 
  1. SMR (↑), GNCR(↑), UNCR(↑).
  2. No point Button is pressed.
  3. No Siding Button is Pressed

G-31 LCNR

- When LXN - Pressed, LXNR - Energized, Provided 

  1. SMR (↑), GNCR(↑), UNCR(↑).
  2. No point Button is pressed.
  3. No CH Button is pressed.
  4. No Siding Button is Pressed